165 lines
6.8 KiB
Plaintext
165 lines
6.8 KiB
Plaintext
VERSION ""
|
||
|
||
|
||
NS_ :
|
||
NS_DESC_
|
||
CM_
|
||
BA_DEF_
|
||
BA_
|
||
VAL_
|
||
CAT_DEF_
|
||
CAT_
|
||
FILTER
|
||
BA_DEF_DEF_
|
||
EV_DATA_
|
||
ENVVAR_DATA_
|
||
SGTYPE_
|
||
SGTYPE_VAL_
|
||
BA_DEF_SGTYPE_
|
||
BA_SGTYPE_
|
||
SIG_TYPE_REF_
|
||
VAL_TABLE_
|
||
SIG_GROUP_
|
||
SIG_VALTYPE_
|
||
SIGTYPE_VALTYPE_
|
||
BO_TX_BU_
|
||
BA_DEF_REL_
|
||
BA_REL_
|
||
BA_DEF_DEF_REL_
|
||
BU_SG_REL_
|
||
BU_EV_REL_
|
||
BU_BO_REL_
|
||
SG_MUL_VAL_
|
||
|
||
BS_:
|
||
|
||
BU_: Parker_watchdog Parker_master PC
|
||
VAL_TABLE_ DCFC_availability 3 "DCFC available and powered up" 2 "DCFC session in progress" 1 "DCFC not available" 0 "DCFC available" ;
|
||
VAL_TABLE_ station_state 6 "Fault" 5 "Station disabled man disabled" 4 "Station disabled very low SOC" 3 "DCFC powered solar production" 2 "DCFC pwrd no solar production" 1 "solar producing no DCFC" 0 "standby" ;
|
||
VAL_TABLE_ DCFC_states 10 "open AC contactors" 9 "DCFC is off" 8 "shutdown DCFC" 7 "session in progress" 6 "DCFC is on" 5 "DCFC starting" 4 "close AC contactors" 3 "not inverting opened cont" 2 "inverting opened contactors" 1 "DCFC start requested" 0 "default" ;
|
||
|
||
|
||
BO_ 258 WDT_to_master: 8 Parker_watchdog
|
||
|
||
BO_ 257 master_to_WDT: 8 Parker_master
|
||
SG_ shutdownAllnonEssential12Vloads : 2|1@1+ (1,0) [0|0] "" Vector__XXX
|
||
SG_ shutdown_PC_pls : 1|1@1+ (1,0) [0|0] "" Vector__XXX
|
||
SG_ shutdown_internet_pls : 0|1@1+ (1,0) [0|0] "" Vector__XXX
|
||
|
||
BO_ 1281 DCFC_LEDs: 8 Parker_master
|
||
SG_ start_btn_was_pressed : 5|1@1+ (1,0) [0|0] "" Vector__XXX
|
||
SG_ RED_LED_SOLID : 4|1@1+ (1,0) [0|0] "" Vector__XXX
|
||
SG_ RED_LED_BLINKING : 3|1@1+ (1,0) [0|0] "" Vector__XXX
|
||
SG_ GREEN_LED_SOLID : 2|1@1+ (1,0) [0|0] "" Vector__XXX
|
||
SG_ GREEN_LED_BLINKING : 1|1@1+ (1,0) [0|0] "" Vector__XXX
|
||
SG_ DCFC_LED_DONT_MATCH_STATE : 0|1@1+ (1,0) [0|0] "" Vector__XXX
|
||
|
||
BO_ 320 heater: 8 Parker_master
|
||
SG_ heater_problem : 8|1@1+ (1,0) [0|0] "" Vector__XXX
|
||
SG_ heater_request : 0|8@1- (1,0) [0|0] "%" Vector__XXX
|
||
|
||
BO_ 260 stationESS6: 8 Parker_master
|
||
SG_ batt4_discharge_cap : 56|8@1+ (2,0) [0|510] "kW" Vector__XXX
|
||
SG_ batt4_charge_cap : 48|8@1+ (1,0) [0|0] "kW" Vector__XXX
|
||
SG_ batt3_discharge_cap : 40|8@1+ (2,0) [0|510] "kW" Vector__XXX
|
||
SG_ batt3_charge_cap : 32|8@1+ (1,0) [0|0] "kW" Vector__XXX
|
||
SG_ batt2_discharge_cap : 24|8@1+ (2,0) [0|510] "kW" Vector__XXX
|
||
SG_ batt2_charge_cap : 16|8@1+ (1,0) [0|0] "kW" Vector__XXX
|
||
SG_ batt1_discharge_cap : 8|8@1+ (2,0) [0|510] "kW" Vector__XXX
|
||
SG_ batt1_charge_cap : 0|8@1+ (1,0) [0|0] "kW" Vector__XXX
|
||
|
||
BO_ 336 DCFC: 8 Parker_master
|
||
SG_ DCFC_state : 0|8@1+ (1,0) [0|0] "" Vector__XXX
|
||
|
||
BO_ 310 fans: 8 Parker_master
|
||
SG_ FAN_power_elec : 1|1@1+ (1,0) [0|0] "" Vector__XXX
|
||
SG_ FAN_cells : 0|1@1+ (1,0) [0|0] "" Vector__XXX
|
||
|
||
BO_ 265 stationESS5: 8 Parker_master
|
||
SG_ minCellBattery4 : 48|16@1+ (1,0) [0|0] "mV" Vector__XXX
|
||
SG_ maxCellBattery4 : 32|16@1+ (1,0) [0|0] "mV" Vector__XXX
|
||
SG_ minCellBattery3 : 16|16@1+ (1,0) [0|0] "mV" Vector__XXX
|
||
SG_ maxCellBattery3 : 0|16@1+ (1,0) [0|0] "mV" Vector__XXX
|
||
|
||
BO_ 264 stationESS4: 8 Parker_master
|
||
SG_ minCellBattery2 : 48|16@1+ (1,0) [0|0] "mV" Vector__XXX
|
||
SG_ maxCellBattery2 : 32|16@1+ (1,0) [0|0] "mV" Vector__XXX
|
||
SG_ minCellBattery1 : 16|16@1+ (1,0) [0|0] "mV" Vector__XXX
|
||
SG_ maxCellBattery1 : 0|16@1+ (1,0) [0|0] "mV" Vector__XXX
|
||
|
||
BO_ 309 temperature2: 8 Parker_master
|
||
SG_ FEEDBACKpowerElectronicPump1 : 16|8@1+ (50,0) [0|0] "RPM" Vector__XXX
|
||
SG_ FEEDBACKcellHeatingPump1 : 8|8@1+ (50,0) [0|0] "RPM" Vector__XXX
|
||
SG_ FEEDBACKcellCoolingPump1 : 0|8@1+ (50,0) [0|0] "RPM" Vector__XXX
|
||
|
||
BO_ 304 temperatures1: 8 Parker_master
|
||
SG_ outside_temp_average_24h : 24|8@1- (1,0) [0|0] "<22>C" Vector__XXX
|
||
SG_ PCS_hottest_temperature : 16|8@1- (1,0) [0|0] "<22>C" Vector__XXX
|
||
SG_ outside_container_temp : 8|8@1- (1,0) [0|0] "<22>C" Vector__XXX
|
||
SG_ inside_container_temp : 0|8@1- (1,0) [0|0] "<22>C" Vector__XXX
|
||
|
||
BO_ 1280 AC_chargers: 8 Parker_master
|
||
SG_ AC_chargers_power : 0|8@1+ (0.25,0) [0|0] "kW" Vector__XXX
|
||
|
||
BO_ 1024 Power_Inverter: 8 Parker_master
|
||
SG_ frequency_bias : 24|8@1- (0.1,0) [0|0] "hz" Vector__XXX
|
||
SG_ main_inverter_hotest_sensor : 16|8@1- (1,0) [0|0] "<22>C" Vector__XXX
|
||
SG_ power_inverter_DC_power : 0|16@1- (0.1,0) [0|0] "kW" Vector__XXX
|
||
|
||
BO_ 263 stationESS3: 8 Parker_master
|
||
SG_ ESS_total_power : 0|16@1- (0.1,0) [0|0] "kW" Vector__XXX
|
||
|
||
BO_ 288 LowVoltageStatus: 8 Parker_master
|
||
SG_ MPPT12vPower : 40|8@1+ (2,0) [0|0] "W" Vector__XXX
|
||
SG_ DCDC2outputCurrent : 32|8@1+ (1,0) [0|0] "A" Vector__XXX
|
||
SG_ DCDC1outputCurrent : 24|8@1+ (1,0) [0|0] "A" Vector__XXX
|
||
SG_ ESS2_12VBatteryVoltage : 16|8@1+ (0.1,0) [0|25.5] "V" Vector__XXX
|
||
SG_ ESS1_12VBatteryVoltage : 8|8@1+ (0.1,0) [0|25.5] "V" Vector__XXX
|
||
SG_ HouseBatteryVoltage : 0|8@1+ (0.1,0) [0|0] "V" Vector__XXX
|
||
|
||
BO_ 262 stationESS2: 8 Parker_master
|
||
SG_ batt4_low_cell_t : 56|8@1- (1,0) [0|0] "<22>C" Vector__XXX
|
||
SG_ batt3_low_cell_t : 48|8@1- (1,0) [0|0] "<22>C" Vector__XXX
|
||
SG_ batt2_low_cell_t : 40|8@1- (1,0) [0|0] "<22>C" Vector__XXX
|
||
SG_ batt1_low_cell_t : 32|8@1- (1,0) [0|0] "<22>C" Vector__XXX
|
||
SG_ batt4_high_cell_t : 24|8@1- (1,0) [0|0] "<22>C" Vector__XXX
|
||
SG_ batt3_high_cell_t : 16|8@1- (1,0) [0|0] "<22>C" Vector__XXX
|
||
SG_ batt2_high_cell_t : 8|8@1- (1,0) [0|0] "<22>C" Vector__XXX
|
||
SG_ batt1_high_cell_t : 0|8@1- (1,0) [0|0] "<22>C" Vector__XXX
|
||
|
||
BO_ 768 PC_dateTime: 8 PC
|
||
SG_ internetSeemsDead : 32|1@1+ (1,0) [0|0] "" Vector__XXX
|
||
|
||
BO_ 512 WDT_state: 8 Parker_watchdog
|
||
|
||
BO_ 277 station_state1: 8 Parker_master
|
||
SG_ DCFC_availability : 16|8@1+ (1,0) [0|0] "" Vector__XXX
|
||
SG_ Station_state : 8|8@1+ (1,0) [0|0] "" Vector__XXX
|
||
SG_ SOCtoDisplay : 0|8@1+ (0.5,0) [0|0] "%" Vector__XXX
|
||
|
||
BO_ 272 station_ver: 8 Parker_master
|
||
|
||
BO_ 261 stationESS1: 8 Parker_master
|
||
SG_ DC_bus_voltage : 48|16@1+ (0.1,0) [0|0] "V" Vector__XXX
|
||
SG_ summed_ESS_current : 32|16@1- (0.1,0) [0|0] "A" Vector__XXX
|
||
SG_ SOC_battery4 : 24|8@1+ (0.5,0) [0|127.5] "%" Vector__XXX
|
||
SG_ SOC_battery3 : 16|8@1+ (0.5,0) [0|127.5] "%" Vector__XXX
|
||
SG_ SOC_battery2 : 8|8@1+ (0.5,0) [0|127.5] "%" Vector__XXX
|
||
SG_ SOC_battery1 : 0|8@1+ (0.5,0) [0|127.5] "%" Vector__XXX
|
||
|
||
BO_ 256 parker_dateTime: 8 Parker_master
|
||
SG_ parker_time : 16|16@1+ (0.001,0) [0|0] "h" Vector__XXX
|
||
SG_ parker_date : 0|16@1+ (1,0) [0|0] "d" Vector__XXX
|
||
|
||
|
||
|
||
CM_ SG_ 263 ESS_total_power "positive values = battery charging";
|
||
CM_ SG_ 256 parker_time "hours elapsed since midnight, for example 18.25";
|
||
CM_ SG_ 256 parker_date "number of days that have passed since 1899-12-30";
|
||
BA_DEF_ "BusType" STRING ;
|
||
BA_DEF_DEF_ "BusType" "";
|
||
VAL_ 336 DCFC_state 10 "open AC contactors" 9 "DCFC is off" 8 "shutdown DCFC" 7 "session in progress" 6 "DCFC is on" 5 "DCFC starting" 4 "close AC contactors" 3 "not inverting opened cont" 2 "inverting opened contactors" 1 "DCFC start requested" 0 "default" ;
|
||
VAL_ 277 DCFC_availability 3 "DCFC available and powered up" 2 "DCFC session in progress" 1 "DCFC not available" 0 "DCFC available" ;
|
||
VAL_ 277 Station_state 6 "Fault" 5 "Station disabled man disabled" 4 "Station disabled very low SOC" 3 "DCFC powered solar production" 2 "DCFC pwrd no solar production" 1 "solar producing no DCFC" 0 "standby" ;
|
||
|