Cleanup répertoire
This commit is contained in:
@@ -0,0 +1,165 @@
|
||||
===============================================================================
|
||||
ReadMe.txt
|
||||
|
||||
PCAN-Basic V4.6.2.753
|
||||
Copyright (c) 2022 PEAK-System Technik GmbH Darmstadt, Germany
|
||||
All rights reserved.
|
||||
===============================================================================
|
||||
|
||||
Maximize the Notepad Window to read this file more easily.
|
||||
|
||||
|
||||
Contents:
|
||||
---------
|
||||
* Introduction
|
||||
* System Requirements
|
||||
* Rights to use these files
|
||||
* Contents of this directory
|
||||
* Installation of PCAN hardware
|
||||
* How to contact PEAK-System Technik GmbH
|
||||
* LIFE SUPPORT APPLIANCES
|
||||
|
||||
|
||||
Introduction
|
||||
------------
|
||||
The PCAN system of the company PEAK-System Technik GmbH consists of a
|
||||
collection of Windows Device Drivers. These allow the Real-time connection of
|
||||
Windows applications to all CAN busses that are physically connected to the PC
|
||||
via a PCAN hardware.
|
||||
|
||||
PCAN-Basic is a simple programming interface to the PCAN system. Via one
|
||||
Interface DLL it is possible to connect own applications to the Device drivers
|
||||
and the PCAN hardware, to communicate with the CAN busses.
|
||||
|
||||
The provided drivers, the PCAN-Basic API, and the PCAN-View CAN bus Monitor
|
||||
software are the feature-reduced versions of the larger software packages
|
||||
PCAN-Developer or PCAN-Explorer. These can be aquired separately.
|
||||
|
||||
|
||||
Rights to use these files
|
||||
-------------------------
|
||||
Please read the End User License Agreement of the company PEAK-System Technik GmbH at:
|
||||
www.peak-system.com/quick/eula
|
||||
|
||||
PEAK-System Technik GmbH grants the right to the customer to use the files in
|
||||
this software package as long as this is done in connection with original
|
||||
hardware by PEAK-System or OEM hardware coming from PEAK-System. It is NOT
|
||||
allowed to use any of these files (even not parts) with third-party hardware.
|
||||
|
||||
If you are not sure whether you have acquired an appropriate license with the
|
||||
used hardware, please contact our technical support team (support@peak-system.com).
|
||||
|
||||
|
||||
System Requirements
|
||||
-------------------
|
||||
- Operating systems: Windows 11 (x64/ARM64), Windows 10 (x64)
|
||||
|
||||
|
||||
Contents of this directory
|
||||
--------------------------
|
||||
ReadMe.txt
|
||||
This text file.
|
||||
|
||||
LiesMich.txt
|
||||
This text file in German language.
|
||||
|
||||
PCANBasic_enu.chm
|
||||
The PCAN-Basic documentation in English.
|
||||
|
||||
PCANBasic_deu.chm
|
||||
The PCAN-Basic documentation in German.
|
||||
|
||||
PCAN-Parameter_Documentation.pdf
|
||||
Additional documentation about PCAN-Basic Get/Set parameters in English.
|
||||
|
||||
\Include
|
||||
- The Header files for different programming languages and development
|
||||
environments.
|
||||
|
||||
\x86
|
||||
- Contains the 32-bit (x86) interface DLL and an x86 demo application (exe).
|
||||
|
||||
\BB_LIB
|
||||
x86 LIB file for C++ Builder.
|
||||
|
||||
\VC_LIB
|
||||
x86 LIB file for Visual C/C++.
|
||||
|
||||
\x64
|
||||
- Contains the 64-bit (x64) interface DLL and an x64 demo application (exe).
|
||||
|
||||
\VC_LIB
|
||||
x64 LIB file for Visual C/C++.
|
||||
|
||||
\ARM64
|
||||
- Contains the ARM64 interface DLL and an ARM64 demo application (exe).
|
||||
|
||||
\VC_LIB
|
||||
ARM64 LIB file for Visual C/C++
|
||||
|
||||
\Samples
|
||||
- Contains example files that demonstrate the use of the PCAN-Basic API in
|
||||
different programming languages and development environments.
|
||||
|
||||
\NuGet
|
||||
- Contains the PCAN-Basic.NET assembly NuGet package.
|
||||
|
||||
|
||||
Installation of PCAN hardware
|
||||
-----------------------------
|
||||
For information on installing PCAN hardware, please refer to the corresponding
|
||||
hardware user manual. These manuals are accessible online at:
|
||||
www.peak-system.com/quick/Documentation.
|
||||
|
||||
The target system requires to have the PCANBasic.dll library installed in order
|
||||
to be able to run applications that use this API. There are two ways to get this
|
||||
library installed on a system:
|
||||
1. Via "Device Driver Setup" (recommended): The same application used for device
|
||||
driver installation can also install this library. It can be downloaded using
|
||||
the following link: www.peak-system.com/quick/DrvSetup.
|
||||
2. Copying the library manually: Copy the library files contained in this package
|
||||
to the target system as follow:
|
||||
|
||||
For x64 Windows systems:
|
||||
\x86\PCANBasic.dll --> Windows\SysWOW64
|
||||
\x64\PCANBasic.dll --> Windows\System32
|
||||
|
||||
For ARM64 Windows systems:
|
||||
\x86\PCANBasic.dll --> Windows\SysWOW64
|
||||
\x64\PCANBasic.dll --> Application folder (x64 applications)
|
||||
\ARM64\PCANBasic.dll --> Application folder (ARM64 applications)
|
||||
|
||||
|
||||
Installation of the NuGet Package
|
||||
---------------------------------
|
||||
Performing an online or offline installation of the NuGet package for Microsoft
|
||||
Visual Studio or Visual Studio Code is described in the documentation of the
|
||||
PCAN-Basic.NET Assembly at https://docs.peak-system.com/API/PCAN-Basic.Net/,
|
||||
in chapter "Introduction\How-To's and Q&A's".
|
||||
|
||||
|
||||
How to contact PEAK-System Technik GmbH
|
||||
---------------------------------------
|
||||
If you have any questions concerning the installation of PCAN hardware, or
|
||||
require information about other PEAK CAN products, then please contact us:
|
||||
|
||||
PEAK-System Technik GmbH
|
||||
Otto-Roehm-Str. 69
|
||||
D-64293 Darmstadt
|
||||
Germany
|
||||
|
||||
Tel. +49 6151 / 8173-20
|
||||
FAX +49 6151 / 8173-29
|
||||
|
||||
support@peak-system.com
|
||||
http://www.peak-system.com
|
||||
|
||||
|
||||
LIFE SUPPORT APPLIANCES
|
||||
-----------------------
|
||||
These products are not designed for use in life support appliances, devices,
|
||||
or systems where malfunction of these products can reasonably be expected to
|
||||
result in personal injury. PEAK-System customers using or selling these
|
||||
products for use in such applications do so at their own risk and agree to
|
||||
fully indemnify PEAK-System for any damages resulting from such improper use
|
||||
or sale.
|
||||
Reference in New Issue
Block a user